Common Point Grounding Units Installation Instructions |
![]() |
|
Description Per ANSI/ESD S20.20, all conductors, including personnel, must be electrically connected and attached to a known ground. EOS/ESD S6.1 recommends hard ground, without resistor, of worksurface or floor mats. Per ANSI/ESD S20.20, ground fault circuit interrupter (GFCI) should be considered to provide personnel protection. ESD Systems.com offers a number of common point grounds and wrist strap ground connectors designed to ground multiple operators or devices. Figure 1. 13523/13525 wrist strap bench ground. The 13523/13525 wrist strap bench ground is a wrist strap ground connector and consists of a mounting bracket with two standard banana jacks installed and soldered to a ten foot ground wire terminated with a ring terminal with a 0.200" hole. The 13523 includes a wrist strap parking station. See figure 2. Figure 2. 13523 premium bench mounted ground with parking station. The 13580 Multi Grounding Hub is designed for use as either a wrist strap ground connector or as a common point ground for all items to be grounded at a bench (i.e. table mat ground cord, floor mat ground cord, banana jack ground block, etc.). The Multi Grounding Hub |
Figure 4. 13570/13575 quad common point ground. The 13570/13575 quad common point ground is designed for use as either a wrist strap ground connector or as a common point ground cord. The quad ground cord incorporates four standard banana jacks, a 10mm (0.395") snap stud, and ten feet of ground wire terminated with a ring terminal with a 0.200" I.D. hole. The model 13570 also incorporates a 1 megohm resistor in series with the snap stud. Figure 5. 13160/13165 common point ground. The 13160/13165 common point ground is designed for use on bench mats to provide a convenient wrist strap ground connector. It incorporates two standard banana jacks, a 10mm (0.395") snap stud, and 15 feet of |
Wire terminated with a ring terminal with a 0.200" I.D. hole. The model 13165 also incorporates a one megohm resistor in series with the snap stud. The 13523/13525 and the 13570/13575 feature a pair of mounting holes designed to accommodate standard #10 screws, allowing the units to be permanently installed at the work bench. Proper Grounding COMMON POINT GROUND Per ANSI/EOS/ESD S6.1, Grounding para- graph 4.1.1 "Every element to be grounded at an ESD protected station shall be con- nected to the same common point ground." ESD Handbook TR 20.20 paragraph 5.1.3 Basic Grounding Requirements "The first step in ensuring that everything in an EPA is at the same electrical potential is to ground all conductive components of the work area (worksurfaces, people, equipment, etc.) to the same electrical ground point. This point is called the common point ground. The next step in completing the ground circuit is to connect the common point ground to the equipment ground (third wire, green)." If all elements are connected to the common point ground, even if the equipment ground connection is compromised, all workstation elements will be connected and be at equi- potential or at the same charge. Being at the same electrostatic charge will mean that no discharge should occur. |
|
Connect the ground wire directly to the nearest utility “green wire” ground point. In a properly wired building, the “green wire” equipment ground point may be the center screw of the standard 110VAC outlet. Some special outlets may “float” the center screw. Test before you hook up. Individual work stations must be individually grounded to the “green wire” equipment ground. For ESD worksurface Always Test the Ground Before You Use It And Periodically Thereafter Installation WRIST STRAP GROUND |
4. To check resistance, use an ohmmeter from the banana jacks to the common ground point. It should read less than 1 Ohm AC impedance for items 13523/13525, 13160 and 13575, and 1 megohm (106 Ohms) for items 13570 and 13165. GROUNDING POINT Figure 9. Installing the 13570/13575 and
|
4. To check resistance, use an ohmmeter from the ground point snap on the mat to the common ground point. It should read 1 megohm ±20 percent if you are using a model 13570 or 13165 ground cord, and less than 1 Ohm AC impedance if you are using a 13575 or 13160 non-resistor ground cord. MULTI GROUNDING HUB Figure 10. Installation of multi grounding Maintenance