Techspray 2211 Wondermask P Safety Data Sheet

Techspray Wondermask P

Section 1. Identification
GHS product identifier : Techspray Wondermask P
Product code : 2211/CAN/EUR-2SQ, 8SQ, G, 5G, 54G
Other means of
identification
: Not available.
Product type : Liquid.

Relevant identified uses of the substance or mixture and uses advised against: Not applicable.

Supplier's details

: Techspray 8125 Cobb Center Drive
  Kennesaw, GA 30152
  Tel: 678-819-1408
  Toll free: 800-858-4043
  Fax: 1 806-372-8750

Emergency telephone number (with hours of operation) : Chemtrec - 1-800-424-9300
  CANUTEC (Canadian Transportation): (613) 996-6666
  Emergency phone: (800) 858-4043 24/7
Section 2. Hazards identification
OSHA/HCS status : While this material is not considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200), this SDS contains valuable information critical to the safe handling and proper use of the product. This SDS should be retained and available for employees and other users of this product.
Classification of the substance or mixture

: Not classified.

  Percentage of the mixture consisting of ingredient(s) of unknown toxicity: 96.5%

GHS label elements  
Signal word : No signal word.
Hazard statements : No known significant effects or critical hazards.
Precautionary statements  
Prevention : Not applicable.
Response : Not applicable.
Storage : Not applicable.
Disposal : Not applicable.
Hazards not otherwise classified : None known.
Section 3. Composition/information on ingredients
Substance/mixture : Mixture
Other means of identification : Not available.

Any concentration shown as a range is to protect confidentiality or is due to batch variation.

There are no ingredients present which, within the current knowledge of the supplier and in the concentrations
applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Occupational exposure limits, if available, are listed in Section 8.

Section 4. First aid measures

Description of necessary first aid measures

Eye contact : Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.
Inhalation : Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.
Skin contact : Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
Ingestion : Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Most important symptoms/effects, acute and delayed

Potential acute health effects

Eye contact : May cause eye irritation.
Inhalation

: Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.

Skin contact : May cause skin irritation.
Ingestion : Do not ingest. If swallowed then seek immediate medical assistance.
Over-exposure signs/symptoms  
Eye contact

: Adverse symptoms may include the following: irritation redness watering

Inhalation :Adverse symptoms may include the following:respiratory tract irritation
Skin contact : Adverse symptoms may include the following:irritation redness
Ingestion : Adverse symptoms may include the following:nausea or vomiting diarrhea Ingestion Seek medical attention.

Indication of immediate medical attention and special treatment needed, if necessary

Notes to physician : In case of inhalation of decomposition products in a fire, symptoms may be delayed.The exposed person may need to be kept under medical surveillance for 48 hours.
Specific treatments : No specific treatment.
Protection of first-aiders : No action shall be taken involving any personal risk or without suitable training.

See toxicological information (Section 11)

Section 5. Fire-fighting measures
Extinguishing media  
Suitable extinguishing media : Use an extinguishing agent suitable for the surrounding fire.
Unsuitable extinguishing media : None known.
Specific hazards arising from the chemical : In a fire or if heated, a pressure increase will occur and the container may burst.
Hazardous thermal decomposition products : Decomposition products may include the following materials:carbon dioxide carbon monoxide nitrogen oxides
Special protective actions for fire-fighters : Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Special protective equipment for fire-fighters : Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Section 6. Accidental release measures

Personal precautions, protective equipment and emergency procedures

For non-emergency personnel : No action shall be taken involving any personal risk or without suitable training.Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.
For emergency responders

: If specialized clothing is required to deal with the spillage, take note of any information in

Section 8 on suitable and unsuitable materials. See also the information in "For non- emergency personnel".

Environmental precautions : Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Methods and materials for containment and cleaning up

Small spill : Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Large spill : Stop leak if without risk. Move containers from spill area. Prevent entry into sewers,water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible,absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a
licensed waste disposal contractor. Note: see Section 1 for emergency contact information and Section 13 for waste disposal.
Section 7. Handling and storage

Precautions for safe handling

Protective measures : Put on appropriate personal protective equipment (see Section 8).
Advice on general occupational hygiene : Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating,drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Conditions for safe storage,including any incompatibilities : Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.
Section 8. Exposure controls/personal protection

Control parameters                 

Occupational exposure limits  : None.
Appropriate engineering controls : Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Environmental exposure controls : Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Individual protection measures  
Hygiene measures : Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period.Appropriate techniques should be used to remove potentially contaminated clothing.Wash contaminated clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.
Eye/face protection :Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists,gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Skin protection  
Hand protection : Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.
Body protection : Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Other skin protection : Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Respiratory protection : Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.
Section 9. Physical and chemical properties
Appearance  
Physical state : Liquid. [gel]
Color : Pink/ Red.
Odor : Not available.
Odor threshold : Not available.
pH : Not available.
Melting point : Not available.
Boiling point : Not available.
Flash point : [Product does not sustain combustion.]
Evaporation rate : Not available.
Flammability (solid, gas) : Not available.
Lower and upper explosive (flammable) limits : Not available.
Vapor pressure : Not available.
Vapor density : Not available.
Relative density : 1
Solubility : Not available.
Solubility in water : Not available.
Partition coefficient: n- octanol/water : Not available.
Auto-ignition temperature : Not available.
Decomposition temperature : Not available.
Viscosity : Not available.
Flow time (ISO 2431) : Not available.
Section 10. Stability and reactivity
Information on toxicological effects  
Acute toxicity : Not available.
Irritation/Corrosion : Not available.
Sensitization : Not available.
Mutagenicity : Not available.
Carcinogenicity : Not available.
Reproductive toxicity : Not available.
Teratogenicity : Not available.
Specific target organ toxicity (single exposure) : Not available.
Specific target organ toxicity (repeated exposure) : Not available.
Aspiration hazard : Not available.
Information on the likely
routes of exposure
: Not available.
Potential acute health effects  
Eye contact : May cause eye irritation.
Inhalation

: Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.

Skin contact : May cause skin irritation.
Ingestion : Do not ingest. If swallowed then seek immediate medical assistance.

Symptoms related to the physical, chemical and toxicological characteristics

Eye contact

: Adverse symptoms may include the following:irritation redness watering

Inhalation :Adverse symptoms may include the following:respiratory tract irritation
Skin contact : Adverse symptoms may include the following:irritation redness
Ingestion : Adverse symptoms may include the following:nausea or vomiting diarrhea Ingestion Seek medical attention.

Delayed and immediate effects and also chronic effects from short and long term exposure 

Short term exposure

Potential immediate effects : Not available.
Potential delayed effects : Not available.
Long term exposure  
Potential immediate effects : Not available.
Potential delayed effects : Not available.
Potential chronic health effects : Not available.
General : No known significant effects or critical hazards.
Carcinogenicity : No known significant effects or critical hazards.
Mutagenicity : No known significant effects or critical hazards.
Teratogenicity : No known significant effects or critical hazards.
Developmental effects : No known significant effects or critical hazards.
Fertility effects : No known significant effects or critical hazards.

Numerical measures of toxicity

Acute toxicity estimates : Not available.
Section 12. Ecological information
Toxicity : Not available.
Persistence and degradability : Not available.
Bioaccumulative potential : Not available.
Mobility in soil  
Soil/water partition coefficient (KOC) : Not available.
Other adverse effects : No known significant effects or critical hazards.
Section 13. Disposal considerations

Disposal methods

 

 

 

 

: The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible. This material and its container must be disposed of in a safe way. Empty containers or liners may retain some product residues. Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Section 14. Transport information
  DOT Classification TDG Classification Mexico Classification ADR/RID IMDG IATA
UN number Not regulated. Not regulated. Not regulated. Not regulated. Not regulated. Not regulated.
UN proper
shipping name
- - - - - -
Transport
hazard class(es)
- - - - - -
Packing group - - - - - -
Environmental
hazards
No. No. No. No. No. No.
Additional
information
- - - - - -
Special precautions for user : Transport within user’s premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.
Transport in bulk according to Annex II of MARPOL and the IBC Code : Not available.
Section 15. Regulatory information
U.S. Federal regulations

: TSCA 8(a) PAIR: 4-Nonylphenol, branched, ethoxylated; 5,12-dihydroquino[2,3-b]
  acridine-7,14-dione

  TSCA 8(a) CDR Exempt/Partial exemption: Not determined

  United States inventory (TSCA 8b): All components are listed or exempted.

  Clean Water Act (CWA) 307: Nitric acid, copper(2+) salt, hydrate (2:1:3)
  Clean Water Act (CWA) 311: Nitric acid, copper(2+) salt, hydrate (2:1:3)

Clean Air Act Section 112 (b) Hazardous Air Pollutants (HAPs) : Not listed
Clean Air Act Section 602 Class I Substances : Not listed
Clean Air Act Section 602 Class II Substances : Not listed
DEA List I Chemicals (Precursor Chemicals) : Not listed
DEA List II Chemicals (Essential Chemicals) : Not listed
SARA 302/304  
Composition/information on ingredients : No products were found.
SARA 304 RQ : Not applicable.
SARA 311/312  
Classification : Not applicable.
Composition/information on ingredients : No products were found.
State regulations  
Massachusetts : None of the components are listed.
New York : None of the components are listed.
New Jersey : None of the components are listed.
Pennsylvania : None of the components are listed.
International regulations  
Chemical Weapon Convention List Schedules I, II & III Chemicals : Not listed.
Montreal Protocol (Annexes A, B, C, E) : Not listed.
Stockholm Convention on Persistent Organic Pollutants : Not listed.
Rotterdam Convention on Prior Informed Consent (PIC) : Not listed.
UNECE Aarhus Protocol on POPs and Heavy Metals : Not listed.

International lists

 

National inventory

 
Australia : Not determined.
Canada : At least one component is not listed in DSL but all such components are listed in NDSL.
China : All components are listed or exempted.
Europe : Not determined.
Japan : Japan inventory (ENCS): Not determined.
  Japan inventory (ISHL): Not determined.
Malaysia : Not determined.
New Zealand : All components are listed or exempted.
Philippines : All components are listed or exempted.
Republic of Korea : Not determined.
Taiwan : All components are listed or exempted.
Turkey : Not determined.
Section 16. Other information

Hazardous Material Information System (U.S.A.)

Caution: HMIS® ratings are based on a 0-4 rating scale, with 0 representing minimal hazards or risks, and 4 representing significant hazards or risks Although HMIS® ratings are not required on SDSs under 29 CFR 1910. 1200, the preparer may choose to provide them. HMIS® ratings are to be used with a fully implemented HMIS® program. HMIS® is a registered mark of the National Paint & Coatings Association (NPCA). HMIS® materials may be purchased exclusively from J. J. Keller (800) 327-6868.

The customer is responsible for determining the PPE code for this material.

National Fire Protection Association (U.S.A.)

                             

Reprinted with permission from NFPA 704-2001, Identification of the Hazards of Materials for Emergency Response Copyright ©1997, National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the National Fire Protection Association, on the referenced subject which is represented only by the standard in its entirety.

Copyright ©2001, National Fire Protection Association, Quincy, MA 02269. This warning system is intended to be interpreted and applied only by properly trained individuals to identify fire, health and reactivity hazards of chemicals. The user is referred to certain limited number of chemicals with recommended classifications in NFPA 49 and NFPA 325, which would be used as a guideline only. Whether the chemicals are classified by NFPA or not, anyone using the 704 systems to classify chemicals does so at their own risk.

Procedure used to derive the classification

Classification Justification
Not classified.  

History

Date of printing : 1/29/2019
Date of issue/Date of revision : 1/29/2019
Date of previous issue : 7/24/2017
Version : 2
Key to abbreviations : ATE = Acute Toxicity Estimate
  BCF = Bioconcentration Factor
  GHS = Globally Harmonized System of Classification and Labelling of Chemicals
  IATA = International Air Transport Association
  IBC = Intermediate Bulk Container
  IMDG = International Maritime Dangerous Goods
  LogPow = logarithm of the octanol/water partition coefficient
  MARPOL = International Convention for the Prevention of Pollution From Ships, 1973
  as modified by the Protocol of 1978. ("Marpol" = marine pollution)
  UN = United Nations
References : Not available.

Indicates information that has changed from previously issued version.

Notice to reader

To the best of our knowledge, the information contained herein is accurate. However, neither the above-named supplier, nor any of its subsidiaries, assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist.

Techspray 1720-A Zero Charge Static Dissipative...
Techspray 2222-8SQ WonderMASK PX Safety Data Sheet