Frequently Asked questions for Pace Fume Extraction

Frequently Asked questions for Pace Fume Extraction

 

Frequently Asked questions for Pace Fume Extraction

1.What type of filter comes with the fume extraction unit?

PACE fume extraction systems are sold with a standard combination filter already installed. The standard filter is a combination pre filter, a high efficiency HEPA filter and a gas filter.

2. Can PACE fume extraction systems remove fumes generated by chemicals or adhesives?

The standard combination filter comes with a gas filter layer to remove trace chemical generated in various electronic soldering applications. An optional adhesive filter is
available for the Arm-Evac 50, 105, 200, and the 250. The optional adhesive filter is designed to absorb larger volumes of chemical and adhesive fumes. The adhesive filters
are made with a combination of activated carbon and activated alumina impregnated with potassium permanganate. They are designed to remove fumes that are generated by
glues, chemical solvents and adhesives.

3. Is there any way to estimate the life of the adhesive filter in my application?

Estimating the life of an adhesive filter is very difficult. Quantifying the amount of chemical or adhesive fumes being absorbed by a system is not an easy task. The removal
capacity of the filter is one way to get a rough estimate of the filters life. The adhesive filter’s removal capacity for some common chemicals is listed below.

Chemical Removal Capacity
Acetone 11.9%
Ammonia <3%
Ethyl cyanoacrylate 21.0%
Formaldehyde 2.0%
n-Heptane 10.0%
Isopropyl Alcohol 21.0%
Methyl-2-cyanoacrylate 20.0%
Methyl Ethyl Ketone (MEK) 21.0%
Toluene 10.0%
Xylene 10.0%

The percentages listed above indicate the weight of a contaminant that can be removed per pound of media in the filter. For example, for every 100 lbs of media, 11.9 lbs of acetone can be absorbed. There is approximately seven pounds of media in the adhesive filter for the Arm-Evac 105, 200, and 250.

If you have a fume removal application that involves a chemical not listed above please contact a PACE technical service representative for the removal capacities for your
application.

4. Can PACE fume extraction systems be used in a cleanroom environment?

A cleanroom filter is available for the Arm-Evac 105, 200, and 250 systems. This filter is ideal for fine particulate and gas removal in designated cleanroom environments.

5. Are the accessories for these systems static safe?

PACE offers a wide variety of accessory options with the Arm-Evac fume extraction systems. The majority of these accessories are ESD safe. Static safe accessory options include metal flex arms, articulated arms, plenums, scoops and suction hoods.

6. How do I know when to change the standard combination filter in my Arm-Evac
200/250 system?

The life of the combination filter can be correlated to the number of rolls of solder that are used with the fume extraction system. Typically the combination filter will last up to
12 – 15, one-pound rolls of solder that are used with the system. The variation is due to the fact that soldering occurs at varying temperatures. At higher soldering temperatures more fumes are produced, thus shortening the life of the filter. The filters typically last from three to twelve months.

7. Is there any way to extend the life of my filter?

The pre-filters should be changed out every one to three weeks. Doing this, will help extend the life of the main filter. The Arm-Evac 105, 200, and 250 has an optional extended life filter that can extend the life of your filter up to four times longer than the standard combo filter. The extended life pre-filter is made of a cotton/polyprop fiber
with an extended wire mesh and has a surface area of 1.25 square feet. The extended life pre-filter must be used with the extended life filter.

8. Are benchtop fume exhausters available?

PACE offers three benchtop fume exhausters. The FX 50 is an affordable benchtop exhauster that draws harmful fumes through an activated carbon impregnated foam filter.
The Turbo Exhauster is a heavy-duty benchtop exhauster with a larger fume capture area. The Turbo Exhauster also uses an activated carbon impregnated foam filter. The Arm- Evac 50 is a unique, portable, cost effective, bench-top fume extractor that provides a wide area fume extraction or highly efficient source capture at two points (using the optional arm attachment).

9. If I have multiple stations can I turn off the airflow to a single station when fume
extraction is not needed?

The airflow to an individual station can be controlled depending on which PACE accessory arms are being used with the system. The 2-inch metal flex arms and the articulated arms come with an adjustable airflow controller that allows an operator to turn off the airflow to a single station. An airflow controller does not come standard with 1.75-inch metal flex arm, but can be added on as an option.

Being able to turn off the airflow to an individual station when it is not in use will improve the overall airflow performance of the remaining stations.

10. Why do fumes generated in electronic soldering operations need to be
extracted?

One of the dangers in electronic assembly is exposure to solder flux fumes. When heated, flux produces airborne pollutants which pose a potential health hazard to workers.
The hazards that are produced by heating flux include formaldehyde, hydrochloric acid, benzene, toluene, styrene, phenol, chlorophenol and isopropyl alcohol.

In addition to the gaseous components of heated flux, a significant amount of particulates are created ranging in size from 0.01 micron to 1.0 micron. Flux fumes closely parallel the particle inhalation range of tobacco smoke. These microscopic particles are readily inhalable and can easily reach the lower respiratory system. These inhaled particles tend to be retained for long periods of time in the lower respiratory tract, promoting adverse chronic pulmonary conditions.

11. Does PACE sell tip extraction systems?

PACE currently has two tip extraction systems for use with up to 60 soldering irons. The two systems offer an easy to install solution for harmful fumes generated by electronic
soldering.

12. What is the expected motor life for the fume extraction systems?

All PACE fume extraction systems are equipped with heavy-duty brushless motors that are specified to last for 20,000 hours. If the systems are turned on for eight hours a day, five days a week the motor will last up to ten years.

13. Can I add more than one fume extraction arm per inlet port?

You can connect two arms to one port by using part number 8882-0692. The kit contains an 8’ section of 3” diameter flex hose, a 3’ section of 3” diameter flex hose with a 3-2” reducer, and a “Y” connector. If the arm requires a 3” diameter hose, the adapter can beremoved to facilitate the installation. Be sure to check the unit specifications so as to not exceed the total number of arms and the maximum ducting length.

14. Can the fume extraction systems such as the Arm-Evac 200 and 250 be used if
resting on its side?

The fume extraction systems are to be operated in the upright position only. They rely on gravity for proper internal sealing of the filter.

15. What is the shelf life of the fume extraction filters?

Generally, if the filter remains as received from PACE (i.e. in a sealed bag), it should keep for approx 2 years. The filter does contain organic compounds that will start to degrade and lose its effectiveness.


Pace Fume Extraction Filter Descriptions

System Filter P/N Filter Size Media/Weight Efficiency Rating Arrestance Rating EU Rating
               
FX 50 8883-0200-P5 Economy Filter 130mm x 130mm x 8mm Activated Carbon impregnated foam      
               
Arm-Evac 50


8883-0125-P5

8883-0300-P5

Pre-Filter

Economy Filter

178mm x 178mm x 4mm

178mm x 178mm x 43mm

Electrostatically charged synthetic fibre. Weight 150g per sq metre. Thickness approx 5mm

  90% EU4
  8883-0280 General Purpose
Filter
178mm x 178mm x 43mm

Glass paper with carbon impregnated foam (as FX50). Media per filter approx 0.5 sq metre

85% ASHRAE   EU8
 

8883-0290

8883-0295

Cleanroom Filter

Adhesive Filter

178mm x 178mm x 43mm

178mm x 178mm x 43mm

Glass paper with carbon impregnated foam (as FX50). Media per filter approx 0.5 sq metre 0.4Kg of 207c Carbon, 20mm thick. Total area 178mm sq.

99.997%

  EU13
               
Arm-Evac 105 8883-0111-P5 Pre-Filter 255mm x 255mm x 20mm Polyester N/A 80-90% EU3/4
Arm-Evac 200 8883-0938-P10 High Capacity
Pre-Filter
250mm x 250mm x 48mm Woven Polyester N/A 90% EU 4
Arm-Evac 250 8883-0871 Economy Filter 254mm x 254mm x 187mm        
 

8883-0931


8883-0931

8883-0936

General Purpose
Filter

Clean Room Filter 

High Capacity
Filter

254mm x 254mm x 187mm

 

254mm x 254mm x 187mm

 

254mm x 254mm x 187mm

Vitreous Borosilicate & gas filter comprised of Potassium Permaganate & Activated Carbon, 0.36kg Carbon based granuals & 40 g Aluminum Oxide in pelleted from impregnated with 4% by weight potassium permanganate.
Vitreous Borosilicate & Bonded Carbon, 0.4 kg 207c coal based Carbon in granuals.

Vitreous Borosilicate

85% ASHRAE




99.997%

65% ASHRAE

N/A



N/A

 

N/A

N/A



EU 13

 

EU 6

  8883-0951 Adhesive Filter 254mm x 254mm x 187mm

700g of Carbon and 400g of purafil. Total weight 1.1kg.

     
               

Arm-Evac 500


8883-0145-P10

8883-0955

Pre-Filter

General Purpose
Filter

305mm x 305mm x 47mm

303mm x 303mm x 150mm

VPleat Pre-Filter in cardboard panel

Vitreous Borosilicate, Mini Pleat in MDF case



90% ASHRAE
 

EU 4

EU8

  8883-0965 Clean RoomFilter 303mm x 303mm x 150mm

Vitreous Borosilicate, Mini Pleat in MDF case

99.997% DOP   EU13
  8883-0956 Carbon Filter 305mm x 305mm x 25mm 207c Carbon in Aluminum Frame      

PACE General Purpose Filter Applications P/N 8883-0931

Due to the size of the Gas filter portion of t he General Purpose Filter Cartridge PACE recommends that it be used in applications when the following substances are being used in small quantities or intermittently. Remember the largest portion of the HEPA / Gas filter cartridge is still the HEPA filter, which is intended for fine particulate filtration. Following are acceptable applications for the General Purpose Filter.

Acetaldehyde Hydrogen Chloride
Acetic Acid Hydrogen Cyanide
Acetone Hydrogen Sulfide
Acetylene Indole
Acrolein Isoprene
Acrylonitrile Methanol
Arsinc Methyl acrylate
Benzene Methyl chloride
1,3-Butadiene Methyl chloroform
Butane Methyl disulfide
Butyric Acid Methyl ethyl ketone (MEK)
Carbon Disulfide Methyl mercaptan
Carbon tetra chloride Methyl sulfide
Chloroform Methyl vinyl ketone Methylamine
Chloropicrin Methylene chloride
Cresol Nitric oxide (NO not Nitrous Oxide N20)
Cyanoacrylate Nitrobenzene
Cyclohexane Ozone
Cyclohexanoic Phenol
1,1 Dichloromethane Phosgene
Diethylamine Phosphine
Dimethylamine Pyridine
Ethanol Silane
Ethyl acetate Skatole
Ethyl acrylate Styrene
Ethylamine Sulphur dioxide
Ethylene Sulphuric acid
Ethylene oxide Sulphur trioxide
Formaldehyde (small quantities) Toluene
Formic Acid Trichloroethylene
Freon 11 VOC's
Hydrazine Xylene
Hydrocarbons (most)  

Why is Fume Extraction Needed?

It's a fact... hazardous fumes in the working environment result in increased absenteeism, employee turnover, worker's compensation claims and lost productivity. Medical research has confirmed an increased incidence of occupational asthma, chronic bronchitis, allergic reactions, contact dermatitis and other health related effects associated with exposure to flux fumes. The substances in flux fumes are regulated by international health and safety agencies and many have been designated as "Occupational Sensitizers" which means that exposure should be eliminated or reduced to as low levels as possible. Where manual soldering is being performed or where solder-pots/fountains are utilized, hazardous fumes are produced and workers need to be protected from them.

FACT: Exposure to Solder Fumes Lead to Respiratory Illness

When rosin-based or rosin-containing fluxes are heated, a substance called colophony is produced which is one of the major causes of occupational asthma. In order to reduce exposure to colophony, rosin-based fluxes have been exchanged for no-clean or synthetic fluxes that contain no rosin or very low percentages. While this reduces or eliminates exposure to colophony, new chemical irritants may be introduced into the work place, many of which pose a more substantial threat to workers. Over 95% of the total fume produced from rosin-based fluxes is in the form of particulates.


Chemical exposure from flux fume varies widely and is dependent on the chemical composition of the flux. Non-rosin or low-rosin fluxes use chemically aggressive substances such as acids, solvents, or alcohols in place of rosin to improve the cleaning action of the flux. Exposure to these substances is also recognized as hazardous and when flux is heated, the resultant chemical by-products can be even more hazardous. Additionally, the use of cleaners, solvents or adhesives, which are common in electronic soldering applications, expose workers to chemical hazards.

The human body has been designed with defense mechanisms such as nasal passageways lined with mucus that will collect larger particles through a process known as impaction and ciliated breathing passageways to remove foreign substances from the main airways of the lungs. Flux fumes contain high levels of respirable particles (less than 3.5 microns in diameter: similar in size to cigarette smoke) that can pass by these natural defense mechanisms, and deposit themselves in the gas-exchange region of the lungs, thereby posing the greatest exposure hazard.

FACT: Material Safety Data Sheets for Fluxes Recommend the Use of Local Exhaust Ventilation Systems

The health effects caused by exposure to flux fumes are generally limited to forms of respiratory illness and contact dermatitis. However, since the components of flux fume are often designated as "Occupational sensitizers", chronic or prolonged exposure increases the severity of health effects. PACE Fume Extraction is a key element in protecting workers from being exposed to flux fume

Pace Worldwide Nitrogen Assisted Soldering Info...
The Future of Component Level Miniature and Mic...