ESD Control Procedures

ESD Control Procedures

ESSENTIAL ELEMENTS OF STATIC CONTROL

We suggested focusing on just six basic principles in the development and implementation of effective ESD control programs:

  1. Design in protection by designing products and assemblies to be as robust as reasonable from ESD’s effects.
  2. Define the level of control needed in your environment.
  3. Identify and define the electrostatic protected areas (EPAs), the areas in which you will be handling ESD susceptible (ESDS) items.
  4. Reduce Electrostatic charge generation by reducing and eliminating static generating processes, keeping processes and materials at the same electrostatic potential, and providing appropriate ground paths to reduce charge generation and accumulation.
  5. Dissipate and neutralize by grounding, ionization, and the use of conductive and dissipative static control materials.
  6. Protect products from ESD with proper grounding or shunting and the use of static control packaging and material handling products.

At the facility level, our ESD control efforts concentrate on the last five principles. Here in Part Three, we will focus on the primary materials and procedures that reduce electrostatic charge generation, remove charges to the ground, and neutralize charges to protect ESDS items.

IDENTIFYING THE PROBLEM AREAS AND THE LEVEL OF CONTROL

One of the first questions we need to answer is, "How sensitive to ESD are the parts and assemblies we are manufacturing or handling?" This information will guide you in determining the various procedures and materials required to control ESD in your environment.

How do you determine your parts and assemblies’ sensitivity, or where can you get information about their ESD classification or withstand voltage? The first source would be the manufacturer or supplier of the component itself or using the part data sheet associated with that component. You must obtain both the Human Body Model (HBM) and Charged-Device Model (CDM) ratings. You may also find that you need to have your specific device tested for ESD sensitivity using ANSI/ESDA/JEDEC JS-001 (HBM) and ANSI/ESDA/JEDEC JS-002 (CDM).  However, be aware that the correlation between voltages used for device qualification and static voltages measured in the field is weak.

The second question you need to answer is, "Which areas of our facility need ESD protection?" This will allow you to define your specific electrostatic protected areas (EPAs), the areas in which you will be handling sensitive parts, and the areas you will need to implement the ESD control principles. Often you will find that more areas require protection than you initially thought, usually wherever exposed ESDS items are handled. Typical areas requiring ESD protection are shown in Table 1.

 

 

GROUNDING

Grounding is especially important for effective ESD control. It should be clearly defined and regularly evaluated. You can check out grounding equipment here

The equipment grounding conductor provides a path to bring ESD protective materials and personnel to the same electrical potential. All conductors and dissipative materials in the environment, including personnel, must be bonded or electrically connected to a known ground, or create an equipotential balance between all items and personnel. ESD protection can be maintained at a charge or potential above a "zero" voltage ground reference as long as all the system items are at the same potential. It is important to note that insulators, by definition, non-conductors, cannot lose their electrostatic charge by connection to the ground.

ESD Association Standard ANSI/ESD S6.1-Grounding recommends a two-step procedure for grounding  ESD control items in the EPA.

The first step is to ground all the workstation components and the personnel (worksurfaces, equipment, etc.) to the same electrical ground point, called the "common point ground." This common point ground is defined as a "system or method for connecting two or more grounding conductors to the same electrical potential."

This ESD common point ground should be correctly identified. ESD Association standard ANSI/ESD S8.1 – Symbols, recommends using the symbol in Figure 1 to identify the common point ground.

The second step is to connect the common point ground to the equipment grounding conductor (AC ground) or the third wire (typically green) electrical ground connection. This is the preferred ground connection because all electrical equipment is already connected to this ground. Clicking the ESD control materials or equipment to the equipment ground brings all the workstation components to the same electrical potential. If a soldering iron used to repair an ESDS item was connected to the electrical ground, and the surface containing the ESDS item was connected to an auxiliary ground, a difference in electrical potential could exist between the iron and the ESDS item. This difference in potential could cause damage to the object.

Any auxiliary ground (water pipe, building frame, ground stake) present and used at the workstation must be bonded to the equipment grounding conductor to minimize potential differences between the two grounds. Detailed information on ESD grounding can be found in ESD Association standard ANSI/ESD S6.1, Grounding, and the ESD Handbook ESD TR20.20, and CLC/TR 61340-5-2 User guide.

 

CONTROLLING STATIC CHARGE ON PERSONNEL AND MOVING EQUIPMENT

People can be one of the prime generators of static electricity. The simple act of walking around or the motions required in repairing a circuit board can generate several thousand volts of electrostatic charge on the human body. If not properly controlled, this static charge can efficiently discharge into an ESDS item – a typical HBM discharge. A person can also transfer the amount to a circuit board or other entity, making it vulnerable to CDM events in a subsequent process.

Even in highly automated assembly and test processes, people still handle ESDS items, this includes but is not limited to: in the warehouse, in repair, in the lab, in transport. For this reason, ESD control programs place considerable emphasis on controlling electrostatic charge on personnel. Similarly, the movement of mobile equipment (such as carts or trolleys) and other wheeled equipment through the facility also can generate substantial static charges that can transfer to the products being transported on this equipment.

WRIST STRAPS

Typically, wrist straps are the primary means of grounding personnel and can also offer equipotential bonding in field service repairs. When properly worn and connected to ground, or the equipotential bonding point, a wrist strap keeps the person wearing it at ground potential or the same potential as the object when the ground connection cannot be achieved. Because the person and other grounded items in the work area are at the same potential, there can be no hazardous discharge between them. Also, static charges are removed from the person to the ground and do not accumulate. When personnel is seated and handling exposed ESDS items, they must be grounded using a wrist strap.

Wrist straps have two major components, the wristband that goes around the person's wrist and the ground cord that connects the wristband to the common point ground.

Most wrist straps have a current limiting resistor molded into the ground cord on the end that connects to the wristband. Per Ohm's Law, the current is equal to voltage divided by resistance; therefore, adding resistance to the "circuit" of the operator to the ground will limit the amount of current flowing through the wrist strap cord. This resistor is most commonly one megohm, rated at least 1/4 watt with a working voltage rating of 250 volts. For personnel safety, if the operator is exposed to 250 volts or higher electrical circuits, wrist straps must not be used.

Wrist straps have several failure mechanisms and, therefore, should be tested regularly. Either daily testing at specific test stations or using a continuous monitor at the workbench is recommended.

FLOORING, FLOOR MATS, FLOOR FINISHES

The second grounding personnel method is a Flooring/Footwear System achieved by using ESD control flooring systems in conjunction with ESD control footwear. This combination of conductive or dissipative floor materials and footwear provides a safe ground path for the dissipation of electrostatic charge, thus reducing personnel’s charge accumulation. In addition to dissipating charge, some floor materials (and floor finishes) also minimize triboelectric charging. The use of a Flooring/Footwear System is especially appropriate in those areas where increased personnel mobility is necessary. Also, floor materials can minimize charge accumulation on chairs, mobile equipment (such as carts and trolleys), lift trucks, and other objects that move across the floor. However, those items require dissipative or conductive casters or wheels to make electrical contact with the floor, and components to be electrically connected. When used as the personnel grounding system, the resistance to the ground, including the person, footwear, and floor, must be less than 1.0 x 109 (ANSI/ESD STM97.1) and the accumulation body voltage in a standard walking voltage test (ANSI/ESD STM97.2) must be less than 100 volts. Please note that both limits must be met.

ESD CONTROL FOOTWEAR, CASTERS

In combination with ESD control flooring systems, ESD control footwear, casters, and wheels provide the necessary electrical contact between the person or object and the flooring system. When working with exposed ESDS items, insulative footwear, casters, or wheels must be avoided. These items prevent static charges from flowing from the body or mobile equipment to the ground through the ESD control items.

CLOTHING  

Clothing is a consideration in most EPAs, especially in cleanrooms and arid environments. Clothing materials, particularly those made of synthetic fabrics, can generate electrostatic charges that may discharge into ESDS items, or they may create electrostatic fields that may induce amounts. Because clothing usually is electrically insulated or isolated from the body, charges on clothing fabrics are not necessarily dissipated to the skin and then to the ground. Static control garments may suppress or otherwise affect an electric field from clothing worn underneath the garment. Per ANSI/ESD S20.20 and the Garment standard ANSI/ESD STM2.1, there are three categories of ESD garment:

  • ESD Category 1 garment; a static control garment without being attached to the ground. However, without grounding, a charge may accumulate on conductive or dissipative elements of a garment, if present, resulting in a charged source.
  • ESD Category 2 garment; a groundable static control garment, when connected to ground, provides a higher level of suppressing an electric field’s effects from clothing worn underneath the garment.
  • ESD Category 3 garment; a groundable static control garment system also bonds the person’s skin to an identified ground path. The total system resistance, including the person, apparel, and grounding cord, shall be less than 35 megohms.

 

WORKSTATIONS AND WORK SURFACES

An ESD protective workstation refers to a single individual’s work area constructed and equipped with materials and equipment to limit damage to ESDS items. It may be a stand-alone station in a stockroom, warehouse, or assembly area, or a field location such as a computer bay in commercial aircraft. A workstation also may be located in a controlled area such as a cleanroom. The critical ESD control elements comprising most workstations are a static dissipative worksurface, a means of grounding personnel (usually a wrist strap), a common point ground, and appropriate signage and labeling. A typical workstation is shown in Figure 2.

The workstation provides a means for connecting all work surfaces, fixtures, handling equipment, and grounding devices to a common ground. There may also be provided for attaching additional personnel grounding devices, equipment, and accessories such as constant or continuous monitors and ionizers.

ESD protective worksurfaces with a resistance to ground of 1.0 x 106 to 1.0 x 109 provide a surface at the same electrical potential as other ESD control items at the workstation. They also provide an electrical path to ground for the controlled dissipation of any static charges on materials that contact the surface. The ESD protective worksurface also helps define a specific work area in which ESDS items are handled. The ESD protective worksurface is connected to the common point ground.

CONTINUOUS OR CONSTANT MONITORS

Continuous (or constant) monitors are designed to provide ongoing testing of the wrist strap system. While several technologies are utilized, the goal remains consistent: electrical connections are tested between the ground point, ground cord, wristband, and person's body while the wearer handles ESDS items. Continuous monitors may also provide a monitoring circuit for the ESD protective worksurface or other equipment connection to the ground reference.

Typical test programs recommend that wrist straps that are used daily should be tested daily. However, if ESDS items are sensitive to a value that a continuous, reliable ground is needed, then continuous monitoring should be considered or even required. Daily wrist strap testing may be omitted if constant monitoring is used. Users should research the different types of continuous monitoring systems, sensitivities of their ESDS items, and which method will work best for their ESD Control Program.

PRODUCTION EQUIPMENT AND PRODUCTION AIDS

Although personnel can be one of the prime generators of electrostatic charge, automated manufacturing and test equipment also can pose an ESD problem. For example, an ESDS item may become charged from sliding down a part feeder. If the device then contacts the insertion head or another conductive surface, a rapid discharge occurs from the device to the metal object, and a CDM event occurs. If charging of the ESDS item cannot be avoided – which is quite often the case in modern assembly lines due to the insulative IC packages – charge stored on packaging materials should be reduced by using ionizers. Besides, various production aids such as hand tools, tapes, or solvents can also be concerns when handling exposed ESDS items.

Grounding is the primary means of controlling static charges on equipment and many production aids. Much electrical equipment is required by the National Electrical Code to be connected to the equipment ground (the green wire) to carry fault currents. This ground connection also will function for ESD control purposes. All electrical tools and equipment used to process or handle ESDS items require the three prong-grounded AC plug. Hand tools that are not electrically powered, i.e., pliers, wire cutters, and tweezers, are usually dropped through the ESD protective worksurface and the grounded person using the conductive/dissipative tools. Holding fixtures should be made of conductive or static dissipative materials when possible; inert dissipative materials are often suggested when susceptible devices are being handled. A separate ground wire may require conductive or dissipative fixtures, not in contact with an ESD protective worksurface or operated by a grounded person. For those composed of insulative materials, the use of ionization or application of topical antistats may be required to control electrostatic charge generation and accumulation of static charges.

GLOVES AND FINGER COTS

Indeed, grounded personnel handling ESDS items should not be wearing gloves or finger cots made from an insulative material. If gloves or finger cots are used, the material should be dissipative or conductive. ESD TR53 provides test procedures for measuring the electrical resistance of gloves or finger cots together with personnel in a system.

PACKAGING MATERIAL HANDLING CONTAINERS

Inside the EPA, packaging and material handling containers are low charging and dissipative or conductive. Outside the EPA, packaging and material handling containers also have a structure that provides electrostatic discharge shielding.

Direct protection of ESDS items from electrostatic discharge is provided by packaging materials such as shielding bags, corrugated boxes, and rigid or semi-rigid plastic packages. The primary use of these items is to protect the product when it leaves the facility, usually when shipped to a customer. Also, material handling containers such as tote boxes and other containers primarily cover inter- or intra-facility transport.

When used with ESDS items, the primary function of packaging and materials handling containers is to limit the possible impact of ESD from triboelectric charge generation, direct discharge, and in some cases, electrostatic fields. The initial consideration is to have low charging materials in contact with ESDS items. For example, the quiet charging property would control the triboelectric charge resulting from a sliding board or component into the package or container. A second requirement is that the material can be grounded, so the resistance range must be conductive or dissipative. A third property required outside the EPA is to protect from direct electrostatic discharges, which would make the packaging and material handling container discharge shielding.

Many materials are available that provide all three properties: low charging, resistance, and discharge shielding. The inside of these packaging materials has a short charging layer and an outer layer with a surface resistance conductive or dissipative range. Per the Packaging standard ANSI/ESD S541, a low-charging, conductive or dissipative package is required for packaging or material handling containers within an EPA. Outside the EPA, the packaging or material handling containers must also have the discharge shielding property. Effectiveness, cost, and device vulnerability to the various mechanisms need to be balanced in making packaging decisions (see ANSI/ESD S541, the ESD Handbook ESD TR20.20, and CLC/TR 61340-5-2 User guide for more detailed information).

Resistance or resistivity measurements help define the material's ability to provide electrostatic shielding or charge dissipation.

  • Electrostatic shielding attenuates electrostatic fields on a package’s surface to prevent a difference in electrical potential from existing inside the container.
  • Discharge shielding is provided by materials that have a surface resistance equal to or less than 1 × 10­3ohm when tested according to ANSI/ESD STM11.11 or volume resistance of similar to or less than one × 10­3ohm-cm when tested according to the methods of ANSI/ESD STM11.12. Besides, effective shielding may be provided by packaging materials that provide a sufficiently large air gap between the package and the ESDS items. Some packages’ ability to provide discharge shielding may be evaluated using ANSI/ESD STM11.31, which measures the energy transferred to the package interior.
  • Dissipative materials provide charge dissipation characteristics. These materials have a surface resistance more excellent than 1 × 10­4ohm but less than 1 × 10­11 ohm when tested according to ANSI/ESD STM11.11 or a volume resistance greater than 1.0 × 105 ohm-cm but less than or equal to 1.0 × 1012 ohm-cm when tested according to the methods of ANSI/ESD STM11.12.
  • Its resistance or resistivity does not necessarily predict a material’s low charging properties.

IONIZATION

Most static control programs also deal with isolated conductors that are not grounded or insulating materials (e.g., most common plastics) that cannot be dropped. Topical antistats may provide temporary ability to dissipate static charges under some circumstances.

More frequently, however, air ionization is used to neutralize the static charge on insulated and isolated objects by producing a balanced source of positively and negatively charged ions. Whatever static charge is present on items in the work environment will be reduced, neutralized by attracting opposite polarity charges from the air. Because it uses only the air already present in the work environment, air ionization may be employed even in cleanrooms where chemical sprays and some static dissipative materials are not usable.

Air ionization is one component of a complete ESD control program and not a substitute for grounding or other methods. Ionizers are used when it is impossible to ground everything and backup to other static control methods properly. In cleanrooms, air ionization may be one of the few ways of static control available.

See Ionization standard ANSI/ESD STM3.1, ANSI/ESD SP3.3, and ESD TR53 for testing offset voltage (balance) and discharge times of ionizers.

CLEANROOMS

While the basic static control methods discussed here are applicable in most environments, cleanroom manufacturing processes require special considerations.

Many objects integral to the semiconductor manufacturing process (quartz, glass, plastic, and ceramic) are inherently charge generating. Because these materials are insulators, this charge cannot be removed by grounding. Many static control materials contain carbon particles or surfactant additives that sometimes restrict their use in cleanrooms. The need for personnel mobility and cleanroom garments often make the use of wrist straps difficult. In these circumstances, ionization and ESD control flooring/footwear systems become key weapons against a static charge.

IDENTIFICATION

A final element in our ESD control program is the use of appropriate symbols to identify ESDS items and specialty products intended to control ESD. The two most widely accepted characters for identifying ESDS items or ESD control protective materials as defined in ESD Association Standard ANSI/ESD S8.1 — ESD Awareness Symbols.

 

The ESD Susceptibility Symbol consists of a triangle, a reaching hand, and a slash through the reaching hand. The triangle means "caution," and the incision through the reaching hand means "Don't touch." Because of its broad usage, the writing in the triangle has become associated with ESD, and the symbol translates to "ESD sensitive stuff, don't touch."

The ESD Susceptibility Symbol is applied directly to integrated circuits, boards, and assemblies that are susceptible to ESD. It indicates that handling or using this item may result in damage from ESD if proper precautions are not taken. Operators should be grounded before handling. If desired, the sensitivity level of the article may be added to the label.

 

The ESD Protective Symbol consists of the reaching hand in the triangle. An arc around the triangle replaces the slash. This "umbrella" means protection. The symbol indicates ESD protective material. It is applied to mats, chairs, wrist straps, garments, packaging, and other items that provide ESD protection. It may also be used on equipment such as hand tools, conveyor belts, or automated handlers that are specially designed or modified to provide ESD control properties (low charging, conductive/dissipative resistance, and discharge shielding).

 

FINALLY

Effective ESD control programs require a variety of procedures and materials. The ESD coordinator should release and control regularly a list of the specific ESD control products permitted to be used in the facility's ESD control program. We have provided a brief overview of the most commonly used products. Additional in-depth discussion of individual materials and procedures can be found in publications such as the ESD Handbook (ESD TR20.20) published by the ESD Association or the CLC/TR 61340-5-2 User guide.

Your program is up and running. How do you determine whether it is effective? How do you make sure your employees follow it? In Part Four, we will cover the topics of Auditing and Training.

 

 

Controlling ESD in Your Manufacturing Process
Controlling ESD in Your Manufacturing Process